Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment
Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment

Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment

2021-08-22 17:22:17   52

Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water TreatmentProduct Overview:Toxicity of metal Cd is low, but high of Cd compounds. Cd poisoning in human body is

  • Material: :
  • Material: :

Cd Online Analyzer/ Cd Online Meter, Water Analyzer, Sewage Water Treatment, Waste Water Treatment

Product Overview

Toxicity of metal Cd is low, but high of Cd compounds. Cd poisoning in human body is mainly caused by the polluted water, food and air, which absorbed by the digestive tract and the respiratory. Cd affects the health of the body slowly. It’s latency can be up to 10~30 years. The Cd, enter into human body and warm-blooded animals, mainly accumulates in the liver, the kidney, the pancreas, the thyroid and the bone. Then the Cd make the kidney and other organs diseases occurred and affects the normal activities of human.

This analyzer can automatic continuous work for long-term in an unattended manner. And it is widely used in industrial pollution discharge wastewater, industrial process wastewater, industrial wastewater treatment plants, municipal wastewater treatment plants and so on. Depending on the complexity at the scene, for ensure reliable and accurate testing, can choose different pre-treatment system.


Product Principle

This product uses dithizone colorimetric method. After mixing the water and the regulator, the Cd and the indicator react to a colored complex, in the acidic environment and the presence of the indicator. The analyzer detects the change of color, converts and outputs the Total Cd value. The amount of the generated colored complex is equivalent to the amount of the Total Cd.

This method is suitable for the waste water, containing of Total Cd within 0~0.5mg/L.

Technical Parameters

No.

Name

Parameter

1

Application range

Suitable for the waste water, containing of Total Cd within 0~0.5mg/L.

2

Test Method

Diphenylthiocarbazone(NC6H5) Spectrophotometric method

3

Measurement Range

0~0.5mg/L

4

Lower limit of detection

0.001

5

Resolution ratio

0.0001

6

Accuracy

±10% Or ±0.0025mg/Lchoose larger value of them

7

Repeatability

5%Or 0.001mg/Lchoose larger value of them

8

Null point drift

±0.05

9

Span drift

±10%

10

Measurement cycle

Minimum test cycle is 20min

11

Sampling cycle

Time interval(adjustable),whole point and trigger measurement mode to choose.

12

Calibration cycle

Auto calibration (adjustable from 1~99 days), manually calibrate according to the actual water samples.

13

Maintenance cycle

Maintenance intervals longer than 1 month, 30min every time.

14

Reagent consumption

Average less than 0.083 USD/sample.

15

Human-machine operation

Touch screen display and command input.

16

Self-checking protection

Self-diagnostic of work condition, data storage when abnormal or power off, Abnormal reset or power on, machine exclude residual reactants and return to work automatically.

17

Data storage

Not less than six months of data storage.

18

Input interface

Switch

19

Output interface

2-way RS232 digital output, 1-way 4~20mA analog output.

20

Work environment

Indoor work, recommended temperature is 5~28, humidity≤90%non-condensing.

21

Power

AC230±10%V50~60Hz5A

22

Size(L x W x H)

450×550×1500mm